XJ-3000直流(liu)接地(di)智能快速(su)查找儀:該裝置由信(xin)號(hao)發(fa)(fa)生(sheng)器(qi)(qi)(qi)、故(gu)(gu)障(zhang)檢測(ce)器(qi)(qi)(qi)和(he)信(xin)號(hao)采集器(qi)(qi)(qi)(鉗表)三部分組成(cheng),信(xin)號(hao)發(fa)(fa)生(sheng)器(qi)(qi)(qi)與直流(liu)系統(tong)正負母線和(he)地(di)相連(lian)(lian),當直流(liu)系統(tong)出現(xian)接地(di)故(gu)(gu)障(zhang)后(hou),它會自(zi)動(dong)產生(sheng)一個低(di)頻小信(xin)號(hao),故(gu)(gu)障(zhang)檢測(ce)器(qi)(qi)(qi)與鉗表獨立(li)于信(xin)號(hao)發(fa)(fa)生(sheng)器(qi)(qi)(qi),故(gu)(gu)障(zhang)檢測(ce)器(qi)(qi)(qi)與鉗表之間使用連(lian)(lian)接線相連(lian)(lian),通(tong)過對待檢測(ce)支(zhi)(zhi)路漏電流(liu)信(xin)號(hao)的采集、分析,從(cong)而(er)判斷出該支(zhi)(zhi)路的絕(jue)緣情況。

在線留言
XJ-3000直流接地智能快速查找儀

XJ-3000直流接地智能快速查找儀

產(chan)品概述:

直(zhi)(zhi)流系(xi)(xi)統(tong)(tong)接(jie)(jie)地(di)(di)是一(yi)種易發生且對電(dian)力系(xi)(xi)統(tong)(tong)危害較大的故(gu)障(zhang)。直(zhi)(zhi)流系(xi)(xi)統(tong)(tong)正極接(jie)(jie)地(di)(di),可能造(zao)成繼(ji)電(dian)保(bao)護誤動(dong)(dong),因(yin)為跳(tiao)閘(zha)線圈接(jie)(jie)直(zhi)(zhi)流電(dian)源負極,系(xi)(xi)統(tong)(tong)再(zai)有一(yi)點接(jie)(jie)地(di)(di)或(huo)絕緣不(bu)良(liang),可能引起保(bao)護誤動(dong)(dong);直(zhi)(zhi)流系(xi)(xi)統(tong)(tong)負極接(jie)(jie)地(di)(di),系(xi)(xi)統(tong)(tong)再(zai)有一(yi)點接(jie)(jie)地(di)(di)或(huo)絕緣不(bu)良(liang),可將跳(tiao)閘(zha)回路或(huo)合閘(zha)回路短路,造(zao)成保(bao)護拒(ju)動(dong)(dong),此時(shi)系(xi)(xi)統(tong)(tong)發生故(gu)障(zhang),保(bao)護的拒(ju)動(dong)(dong)必然導致(zhi)系(xi)(xi)統(tong)(tong)事故(gu)擴(kuo)大,同時(shi)還可能燒壞繼(ji)電(dian)器的觸點或(huo)燒。

我公司自主設(she)計制(zhi)造的(de)(de)(de)便攜式直(zhi)(zhi)流接(jie)地(di)查找儀,能夠適(shi)用于(yu)任何電壓等級的(de)(de)(de)直(zhi)(zhi)流系統,配備(bei)了(le)(le)高精度的(de)(de)(de)檢(jian)測(ce)(ce)鉗表(biao),通過對(dui)多種信號的(de)(de)(de)處理(li)大(da)大(da)提(ti)高了(le)(le)檢(jian)測(ce)(ce)范圍(wei)(wei)與抗干擾能力;采用了(le)(le)*計算方法和模(mo)糊(hu)控制(zhi)理(li)論,將(jiang)被(bei)檢(jian)測(ce)(ce)支路的(de)(de)(de)絕(jue)(jue)緣(yuan)程度以絕(jue)(jue)緣(yuan)指(zhi)數(shu)及波形的(de)(de)(de)形式表(biao)示(shi)出來(lai),充(chong)分(fen)體現(xian)了(le)(le)人工智能的(de)(de)(de)優越性;對(dui)于(yu)接(jie)地(di)點(dian)位(wei)(wei)置的(de)(de)(de)斷定,它們更是擁有(you)準確的(de)(de)(de)判(pan)斷力,每次檢(jian)測(ce)(ce)都能夠指(zhi)出接(jie)地(di)點(dian)位(wei)(wei)置相對(dui)檢(jian)測(ce)(ce)點(dian)的(de)(de)(de)方向(xiang),從而快速(su)、準確地(di)實現(xian)環路接(jie)地(di)檢(jian)測(ce)(ce)。除此之外,用戶可以根據自身系統需要在絕(jue)(jue)緣(yuan)告警門(men)限值(zhi)范圍(wei)(wei)內訂制(zhi)合適(shi)的(de)(de)(de)絕(jue)(jue)緣(yuan)告警門(men)限值(zhi)的(de)(de)(de)設(she)備(bei),用戶只(zhi)需要將(jiang)鉗表(biao)上的(de)(de)(de)檔位(wei)(wei)與檢(jian)測(ce)(ce)器(qi)上的(de)(de)(de)量程對(dui)應起來(lai)就能實現(xian)直(zhi)(zhi)流接(jie)地(di)的(de)(de)(de)檢(jian)測(ce)(ce)或者是絕(jue)(jue)緣(yuan)程度的(de)(de)(de)分(fen)析。

不僅重點解(jie)(jie)決了(le)直流系統(tong)間接(jie)接(jie)地、非金屬接(jie)地、環路(lu)接(jie)地、正負(fu)同(tong)時(shi)接(jie)地、正負(fu)平衡接(jie)地、多點接(jie)地等疑難故障的準(zhun)確檢測(ce),并且還能準(zhun)確的顯示系統(tong)電(dian)壓、對(dui)地電(dian)壓、接(jie)地阻值,真正解(jie)(jie)決了(le)運(yun)行(xing)(xing)及檢修人員(yuan)的后顧之(zhi)憂。本裝置以系統(tong)為首要前提,按行(xing)(xing)業標準(zhun)的要求,以可(ke)靠的低頻(pin)信號方式進行(xing)(xing)檢測(ce),并在現場進行(xing)(xing)了(le)大量的實際應用,對(dui)系統(tong)無任何影(ying)響(xiang)。

XJ-3000直流接地智能快速查找儀

一、 裝置構成及原理 

裝(zhuang)置的(de)構(gou)成(cheng)

該裝置(zhi)由信(xin)(xin)(xin)號(hao)發(fa)(fa)生器(qi)(qi)、故(gu)障檢(jian)測(ce)器(qi)(qi)和信(xin)(xin)(xin)號(hao)采(cai)集器(qi)(qi)(鉗(qian)(qian)表)三(san)部分組成,信(xin)(xin)(xin)號(hao)發(fa)(fa)生器(qi)(qi)與(yu)直(zhi)(zhi)流(liu)系統(tong)正負母線(xian)和地相連,當直(zhi)(zhi)流(liu)系統(tong)出(chu)現(xian)接地故(gu)障后,它會自(zi)動產生一個低(di)頻小信(xin)(xin)(xin)號(hao),故(gu)障檢(jian)測(ce)器(qi)(qi)與(yu)鉗(qian)(qian)表獨立(li)于信(xin)(xin)(xin)號(hao)發(fa)(fa)生器(qi)(qi),故(gu)障檢(jian)測(ce)器(qi)(qi)與(yu)鉗(qian)(qian)表之(zhi)間使用連接線(xian)相連,通過對待檢(jian)測(ce)支路(lu)漏(lou)電流(liu)信(xin)(xin)(xin)號(hao)的采(cai)集、分析,從而判斷(duan)出(chu)該支路(lu)的絕緣情況(kuang)。

2.2 裝置的工作原理

定位裝(zhuang)置的(de)工作原理是:當直(zhi)流系(xi)統(tong)發(fa)(fa)(fa)(fa)生接地(di)(di)故障(zhang)或絕緣(yuan)降低(整個直(zhi)流系(xi)統(tong)絕緣(yuan)電(dian)阻(zu)小(xiao)于(yu)報警(jing)(jing)整定值),直(zhi)流系(xi)統(tong)電(dian)壓(ya)(ya)(ya)監(jian)測裝(zhuang)置發(fa)(fa)(fa)(fa)出(chu)警(jing)(jing)報時(shi),將信(xin)號發(fa)(fa)(fa)(fa)生器(qi)接入直(zhi)流系(xi)統(tong)的(de)正(zheng)(zheng)(zheng)、負(fu)(fu)母(mu)線(xian)和地(di)(di)之間。信(xin)號發(fa)(fa)(fa)(fa)生器(qi)自動判(pan)斷(duan)直(zhi)流系(xi)統(tong)電(dian)壓(ya)(ya)(ya)等(deng)級,自動判(pan)斷(duan)接地(di)(di)故障(zhang)的(de)極性、接地(di)(di)程(cheng)度,自動分析絕緣(yuan)監(jian)測平衡(heng)電(dian)橋回路接線(xian)方式和平衡(heng)電(dian)橋電(dian)阻(zu)大小(xiao),形(xing)成信(xin)號輸出(chu)的(de)智能(neng)反饋,向直(zhi)流正(zheng)(zheng)(zheng)負(fu)(fu)母(mu)線(xian)和地(di)(di)間,發(fa)(fa)(fa)(fa)射適宜系(xi)統(tong)檢測,對系(xi)統(tong)無(wu)影響的(de)低頻信(xin)號,并實時(shi)顯示系(xi)統(tong)電(dian)壓(ya)(ya)(ya)、正(zheng)(zheng)(zheng)對地(di)(di)電(dian)壓(ya)(ya)(ya)、負(fu)(fu)對地(di)(di)電(dian)壓(ya)(ya)(ya)和系(xi)統(tong)對地(di)(di)絕緣(yuan)總(zong)阻(zu)抗。

故(gu)(gu)(gu)障檢(jian)(jian)測器(qi)檢(jian)(jian)測各回(hui)(hui)路(lu)對地(di)絕緣的直流(liu)信(xin)號漏電(dian)流(liu),并模擬顯示接(jie)地(di)回(hui)(hui)路(lu)絕緣狀態(tai),判斷出接(jie)地(di)故(gu)(gu)(gu)障回(hui)(hui)路(lu)(支(zhi)路(lu)),并繼續沿(yan)故(gu)(gu)(gu)障回(hui)(hui)路(lu)(支(zhi)路(lu))檢(jian)(jian)測出接(jie)地(di)故(gu)(gu)(gu)障,將故(gu)(gu)(gu)障點準確定位(wei)。

信(xin)號(hao)發生器、故(gu)障(zhang)(zhang)檢(jian)(jian)測(ce)器均采用微計算(suan)(suan)機(ji)技(ji)術,具(ju)有(you)集(ji)成程度高(gao),判(pan)斷(duan)速(su)度快,檢(jian)(jian)測(ce)靈敏度高(gao)、抗干(gan)擾(rao)能力強(qiang)、故(gu)障(zhang)(zhang)定(ding)位準確等特點(dian)(dian)。在(zai)(zai)軟件處理上利(li)用了模糊控制理論(lun)和通(tong)信(xin)的(de)(de)噪(zao)聲理論(lun),并依(yi)據直(zhi)流系統(tong)的(de)(de)特點(dian)(dian)優(you)化了算(suan)(suan)法(fa),即使系統(tong)有(you)大分布電(dian)容的(de)(de)干(gan)擾(rao)、電(dian)磁脈沖(chong)干(gan)擾(rao)和其它噪(zao)聲干(gan)擾(rao)的(de)(de)影響,也能準確地(di)(di)判(pan)斷(duan)出(chu)接地(di)(di)故(gu)障(zhang)(zhang)點(dian)(dian),為接地(di)(di)故(gu)障(zhang)(zhang)的(de)(de)查找提供了有(you)力的(de)(de)保(bao)障(zhang)(zhang)。在(zai)(zai)硬(ying)件上引進國外*的(de)(de)檢(jian)(jian)測(ce)傳感(gan)器,直(zhi)流信(xin)號(hao)檢(jian)(jian)測(ce)靈敏度高(gao)達0. 1mA,可檢(jian)(jian)測(ce)150K-500K接地(di)(di)的(de)(de)檢(jian)(jian)測(ce)靈敏度,使多點(dian)(dian)接地(di)(di)、環路接地(di)(di)、絕緣普遍(bian)降(jiang)低等難以解決的(de)(de)問題(ti)迎刃而解。

二、 裝置主要(yao)特點

高精度采樣鉗(qian)表

該裝置采(cai)(cai)用了(le)高(gao)分辨率(lv)(0. 1mA)信號(hao)采(cai)(cai)樣直流鉗表(biao),能夠實現對多點(dian)(dian)接(jie)地,高(gao)阻接(jie)地點(dian)(dian)的(de)定(ding)位;

3.2 接(jie)地點方向(xiang)顯(xian)示

該(gai)裝置具有接地(di)點(dian)方向顯示,可(ke)以快速的處理(li)復雜支(zhi)路(lu)或環路(lu)中接地(di)點(dian)的定位;

3.3 具有絕(jue)緣指(zhi)數顯(xian)示(shi)功(gong)能

絕(jue)緣(yuan)指數是為分析待測支(zhi)路絕(jue)緣(yuan)程度而引入說法,以0—100的(de)數字(zi)形式來反映被測支(zhi)路的(de)絕(jue)緣(yuan)程度,數字(zi)越(yue)大表示(shi)絕(jue)緣(yuan)越(yue)差,該指數結合高精度鉗(qian)表非常有利(li)于(yu)多點(dian)接(jie)地(di)與(yu)高阻接(jie)地(di)的(de)檢測。

3.4 具有波形顯示功能

所(suo)(suo)謂波形(xing)(xing)顯(xian)示,即在檢(jian)(jian)測(ce)(ce)過程中檢(jian)(jian)測(ce)(ce)器(qi)所(suo)(suo)搜索到(dao)的(de)(de)信號發生器(qi)的(de)(de)波形(xing)(xing),其在查(cha)找接地過程中有非常重要(yao)的(de)(de)作(zuo)用,合(he)理利用檢(jian)(jian)測(ce)(ce)器(qi)中的(de)(de)波形(xing)(xing)顯(xian)示,可以大幅度(du)的(de)(de)提升設備的(de)(de)檢(jian)(jian)測(ce)(ce)范圍與檢(jian)(jian)測(ce)(ce)精度(du)以判斷的(de)(de)準確度(du)。

3.5 操作(zuo)簡(jian)單(dan),使用方(fang)便(bian)、快速

使用(yong)時只需將鉗表鉗住待(dai)測支路,按一下工作按鍵(jian),3—6S即可完(wan)成一條支路的(de)檢測。

3.6 信號(hao)發(fa)生器與檢測(ce)器不受距離限(xian)制

在復雜的(de)直流(liu)系(xi)統中(zhong),信號(hao)發生器接(jie)入點(dian)(dian)(dian)可能與接(jie)地查(cha)找(zhao)點(dian)(dian)(dian)有著很長的(de)一段距離,不過檢測器并不受此距離的(de)限制,可以在同一個(ge)系(xi)統中(zhong)的(de)任何一點(dian)(dian)(dian)進(jin)行查(cha)找(zhao)。

3.7 運行、可靠

信(xin)號(hao)發(fa)生器是需要接入直(zhi)(zhi)流系統(tong)之中(zhong)的(de),這就對設備的(de)性與根據直(zhi)(zhi)流系統(tong)現場的(de)實際情(qing)況,信(xin)號(hao)發(fa)生器可智能式產生1.0—5.0mA 的(de)信(xin)號(hao)電流,且功(gong)率小于0.2W,適用于各類直(zhi)(zhi)流系統(tong),對直(zhi)(zhi)流系統(tong)的(de)運(yun)行、可靠運(yun)行提供(gong)了保障。

三、 裝置主要技術指標

可(ke)檢測接地(di)電阻范圍

系(xi)統電壓為220V時:0 -500KΩ

系統(tong)電壓為110V時(shi):0 -250KΩ

系統電壓為48V時: 0 -50KΩ

系(xi)統(tong)電壓為24V時:0 -10KΩ

4.2 檢測信號(hao)功(gong)率(lv) ≤ 0.2W(信號(hao)發生器輸出功(gong)率(lv))

4.3 抗(kang)對(dui)地分布(bu)電容值:

對地電(dian)容(rong)單(dan)支路≤8uF,系統對地總(zong)電(dian)容(rong)≤100uF;

4.4 適用直流系統電壓:

220V±10%,110V±10%,48V±10%,24V±10%,或(huo)用戶提出其它電壓等(deng)級;

4.5環(huan)境溫度:-35℃~+55℃;

4.6 相對(dui)濕度:≤95%

4.7總質量:2.8kg

4.8 外(wai)形尺寸(鋁合(he)金包裝箱):460x240x120(mm)